Skip to main content
× Home Products Downloads About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
cart
 
Login Icon
login

Keyword       Ideal Spectroscopy Part Number       Manufacturer Part Number

× Molecular-Spectroscopy Optical-Table-Accessories Absorption-Spectroscopy-Gas-Cells Ultra-High Purity Gas Products Pulse-Valves-For-Jet-Cooling Vacuum-Pressure-Measurement Fittings-and-Flanges Vacuum-Valves Vacuum-Pumps Modular-Vacuum-Chambers

Condition:
  New
Part Number:
  P106248
Warranty:
  Edwards Warranty

Available Now: 
1  



$16,645.99


Regular Price: $25,609.22

On Sale Flyer
Print Version

Edwards nEXT730D Turbo Pump Package Deal with ISO-K 160 Inlet, EPS 800 Power Supply, TAG Controller, and Water-Cooling Kit.


Edwards nEXT730D Turbo Pump Package Deal with ISO-K 160 Inlet, EPS 800 Power Supply, TAG Controller, and Water-Cooling Kit.

This Edwards nEXT730D turbo pump package deal with ISO-K 160 inlet flange has a pumping speed of 820 l/s and an ultimate pressure of 3.5 x 10-9 mbar (2.6 x 10-9 Torr). Included is an EPS 800 power supply with AC power cord, and a mounting bracket to affix the power supply directly onto the pump. Also included are a TAG (turbo & active gauge) controller with large LED display to show the pump's speed or vacuum pressure, along with its power supply and AC power cord. This package features a water-cooling kit to keep the turbo pump running cool. This turbo pump package deal does not include the roughing pump, roughing lines, vacuum chamber, pressure measurement gauges, or vent valves. Some upgrades might include: a TIC controller and TIC relay box to provide better system automation & control, a forced air-cooling kit, and extension cables to extend the distance between the pump, power supply, and controller. All these items are available and sold separately by Ideal Vacuum.

About the nEXT730D turbo pump with ISO-K 160 flange
Edwards nEXT7300D turbomolecular high vacuum pumps with an ISO-K 160 inlet flange have a pumping speed of 820 liters per second (l/s) and an ultimate pressure of 3.5 x 10-9 mbar (2.6 x 10-9 Torr). This nEXT730D pump has an ISO KF-40 exhaust foreline flange. Optional inlet screens (coarse or fine) are available. The nEXT730D series turbo pumps require 48 VDC input power at a maximum of 600 Watts (normal operation is typically less than 500 Watts). A permanently attached 0.6 meter long 48 volt power cable and a 0.95 meter long control cable are standard to the pump. nEXT730D turbo pumps have a compact onboard controller with RS232, RS485, & USB interfaces, five status LED's, and the possibility to control either an air-cooling fan or solenoid vent valve (a "Y" connector is available for connecting both a fan and valve). The USB port allows the use of Edwards nST2 PC software (free download from link below). This nEXT730D turbo pump has Edwards part number B8J200300.

About the EPS 800 power supply
The Edwards EPS 800 is an 800 Watt power supply, provides 48 VDC output at a maximum of 17.1 Amps, and is designed to power nEXT series turbo pump models nEXT730D, nEXT930D, and nEXT1230H. It supplies 48 VDC clean fused power from a 100-240 VAC input source. A 2.5 meter long, 115 VAC AC power cord with US 5-15P plug is included. To mount the EPS 800 to the side of the turbo pump, this package deal also includes an adaptor mounting kit. The power supply connects directly to the pump's attached 48 VDC power cable. The EPS 800 power supply supercedes the (now discontinued) EPS 500 unit and has Edwards part number B8J200819.

About the TAG (turbo and active gauge) controller
The Edwards TAG (turbo & active gauge) controller comes with a 200-Watt external power supply and 2 meter long 115 VAC US power cord (5-15P to C13 connectors). The TAG is a small low-cost 24 VDC pumping system controller, is ideal for use on benchtops or mobile platforms where space is limited, and is suitable for a wide range of vacuum applications. The TAG provides a serial interface for displaying the turbo pump's speed of any nEXT turbo pump, can power the nEXT85D, nEXT240D, nEXT300D, or nEXT400D turbo pumps, and can control an Edwards APG, AIM, ASG, or WRG vacuum gauge. The TAG's push button interface allows the user to easily switch between pump speed or vacuum pressure, shown on the large LED display. The Edwards part number for this TAG controller is D39592000 and its power supply is D39592800.

About the water-cooling kit
The Edwards water cooling unit slides into a slot in the base of the pump and is secured with 4 M4 screws. It has push-fit connectors for the supply and discharge hoses (6mm OD plastic hose). The hose connections may be unscrewed and removed to make use of the integrated G 1/8” threads. Water-cooling is recommended on larger turbo pumps to better regulate the pump's temperature and required when using a flange heater band with a CF flanged pump. Edwards nEXT turbo pumps also benefit from water cooling when there are high gas throughputs, cyclic operations and/or high ambient temperatures. In order to ensure long trouble-free operation, the cooling water must be clean and not contain any oils, greases or suspended solids. This water cooling kit has Edwards part number B8J200820.

Applications for this package deal include:
  • Mass Spectrometry
  • Gas Chromatography Mass Spectrometry (GC/MS)
  • Liquid Chromatography Mass Spectrometry (LC/MS)
  • Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
  • Time-of-Flight Mass Spectrometry (TOF)
Vacuum in Research and Development:
  • High Energy Physics
  • Fusion Technology
  • General UHV Research
  • Synchrotron Light Sources Particle Accelerators
Nanotechnology Instruments:
  • Electron Microscopy
  • Scanning Electron Microscopy (SEM)
  • Transmission Electron Microscopy (TEM)
  • Focused Ion-beam Systems (FIB)
  • Surface Analysis
  • Semiconductor Manufacturing
Industrial Vacuum Processing:
  • Thin Film Deposition:
    • Glass coating equipment (architectural and automotive glass, flat panel displays)
    • Thin film solar cells production (photo-voltaic)
    • Optical data media (CD, DVD, Magneto Optical Discs)
    • Magnetic storage media
    • Surface treatments
    • Optical coating (ophthalmic, precision opto-electronics)
    • Roll/Web coating on films or foils
    Device Processing:
    • TV & Monitor picture tube manufacture
    • Evacuation of lamps (motorway lighting, beamers)
    • X-Ray tubes & electron devices
    General Processes:
    • Vacuum Furnaces
    • Metallurgy
    This package deal is stored in our inventory as a kit, being made up of many separate parts, and the availability of each is shown in the Kit Components section below. The operating instructions manual and Edwards nEXT series product brochures are available in the downloads.



Press ESC to Close




Availability Of Kit Components

Kit: P106248 - Edwards nEXT730D Turbo Pump Package Deal with ISO-K 160 Inlet, EPS 800 Power Supply, TAG Controller, and Water-Cooling Kit.
Component
Desc.
Req'd
Avail
Edwards Water Cooling Kit for nEXT Turbo Pumps with Push-Fit Connectors for 8mm OD Hose, and G 1/8 in. Fittings. PN: B8J200820
1
3
Edwards EPS 800 Power Supply with 48VDC Output for large nEXT Turbo Pumps. PN: B8J200819
1
3
Edwards nEXT730D Turbo Vacuum Pump with ISO-K 160 Inlet Flange 820 l/s Pumping Speed Air or Water Cooled. PN: B8J200300
1
1
Edwards Mounting Kit Adapts EPS 800 Power Supply to side of nEXT Turbo Pumps. PN: B8J200832
1
6
Edwards 2.5m Long 115 VAC Input Power Cord Mains Cable for Edwards EPS 800 Power Supply US Plug. PN: B8J200830
1
100
Edwards 2m Long DB15 Extension Power and Communication Cable Connects TIC or TAG Controller to any nEXT Turbo Pump. PN: D39700836
1
10
Input Power Cord Mains Cable 2m Long 115 VAC for Edwards TIC Controller, Relay Box, TAG Power Supply. US Plug.
1
97
Edwards TAG Turbo and Active Gauge Controller Without 24 VDC Power Supply Used With nEXT Turbo Pumps. PN: D39592000
1
2
Edwards 200W External Power Supply with 24 VDC Output for Edwards TAG Turbo and Active Gauge Controller. PN: D39592800
1
11
PDF Logo Edwards nEXT 730D 930D 1230H Turbo Pumps Instruction Manual.pdf

PDF Logo Edwards nEXT 730D 930D 1230H Turbo Pump Datasheet.pdf

PDF Logo Edwards nEXT 730D 930D Turbo Pump Brochure.pdf

PDF Logo Edwards nEXT Turbomolecular Pumps Entire Range Brochure.pdf

PDF Logo Edwards EPS 800 Power Supply for nEXT 730D 930D 1230H Turbo Pumps Instruction Manual.pdf

PDF Logo Edwards TAG Turbo and Active Gauge Controller Instruction Manual.pdf

PDF Logo Edwards TAG Turbo and Active Gauge Controller Data Sheet.pdf

PDF Logo Edwards nST2 Software FREE Download



You may wish to consider the following products:

Ideal Vacuum Logo Water Mark
CONTACT US
Ideal Spectroscopy
5910 Midway Park Blvd NE,
Albuquerque, NM 87109-5805

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealspectroscopy.com



Press ESC to Close


deepbox image 2