Skip to main content
× Home Products Downloads About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
cart
 
Login Icon
login

Keyword       Ideal Spectroscopy Part Number       Manufacturer Part Number

× Molecular-Spectroscopy Optical-Table-Accessories Absorption-Spectroscopy-Gas-Cells Ultra-High Purity Gas Products Pulse-Valves-For-Jet-Cooling Vacuum-Pressure-Measurement Fittings-and-Flanges Vacuum-Valves Vacuum-Pumps Modular-Vacuum-Chambers

Condition:
  New
Part Number:
  P1013487
Warranty:
  Full Manufacturer's Warranty
Out of Stock  
Expecting:   1
Anticipated Arrival:  1 on 2024-12-09

RoHS Compliance Sticker


$2,331.00


Print Version

Replacement Probe for Ideal Vacuum AnalyzaVAC Residual Gas Analyzer (RGA) 1-100 AMU without Electron Multiplier


Replacement Probe for Ideal Vacuum AnalyzaVAC Residual Gas Analyzer (RGA) 1-100 AMU without Electron Multiplier.

This listing is for the sale of a replacement probe for the model AV100, 1-100 AMU Ideal Vacuum AnalyzaVAC Residual Gas Analyzer without an electron multiplier.

It includes the probe with mass filter, ionizer assembly, and dual thoria coated iridium filaments.

Note that the AnalyzaVac RGA cannot be field upgraded with a probe of a different AMU range nor can an electron multiplier be added to an RGA without one. If you would like to upgrade the AMU range or add an electron multiplier, the RGA must be sent to Ideal Vacuum for a factory electronics upgrade along with the new probe or multiplier. Please contact your sales representative for options.

Please read carefully before ordering:
* The AnalyzaVAC probe is a delicate instrument. Inappropriate use, mishandling of the probe, or operating at elevated pressures for extended amounts of time can contaminate and damage it. Therefore, the probe does not carry a warranty after removal from its original packaging.

The optimal total operational pressure of the RGA is 2×10-7 Torr for most gases. Operation at higher pressures for extended lengths of time will results in premature aging of the probe, loss of gain, spectral drift, and fillament and ionizer burnout. The RGA can be used at the following pressure regions for the corresponding lengths of time:
10-4 Torr, several hours
10-5 Torr, several days
10-6 Torr, several months
10-7 Torr, several years
10-8 Torr, indefinitely
Organic vapors should be kept at a 2x lower pressure than atmospheric gases to prevent soot contamination of the fillament and ionizer. Silicone vapors should be kept at pressures at least 10x lower than atmospheric gases to prevent glass buildup on the fillament and ionizer. Corrosive vapors are also more damaging to the RGA than normal gases. By properly managing pressure, the RGA can be used to measure these gases without incurring costly repairs.



Press ESC to Close




AnalyzaVAC REPLACEMENT PARTS
STYLE
100
100
Bare RGA
High Press. Kit
Range
1-100
1-100
Electron Multiplier
No
Yes
PART
New Probe
Refurbished Probe
P1013521
P1013527
Replac. Filament
Replac. Ionizer
Replac. Electron Multiplier
No
STYLE
200
200
Bare RGA
High Press. Kit
Range
1-200
1-200
Electron Multiplier
No
Yes
PART
New Probe
Refurbished Probe
P1013522
P1013528
Replac. Filament
Replac. Ionizer
Replac. Electron Multiplier
No
STYLE
300
300
Bare RGA
High Press. Kit
Range
1-300
1-300
Electron Multiplier
No
Yes
PART
New Probe
Refurbished Probe
P1013523
P1013529
Replac. Filament
Replac. Ionizer
Replac. Electron Multiplier
No
PDF Logo RoHS Compliance Download

PDF Logo IVP AnalyzaVac RGA User Manual v1.2.1.0.pdf



You may wish to consider the following products:

Ideal Vacuum Logo Water Mark
CONTACT US
Ideal Spectroscopy
5910 Midway Park Blvd NE,
Albuquerque, NM 87109-5805

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealspectroscopy.com



Press ESC to Close


deepbox image 2