Ideal Vacuum AutoZ+ Software Premium Version, Annual Renewal License, for all AnalyzaVAC Residual Gas Analyzers (RGAs)


Ideal Vacuum AutoZ+ Software Premium Version, Annual Renewal License, for all AnalyzaVAC Residual Gas Analyzers (RGAs).

This listing is for the purchase of an annual renewal license of the premium version of AutoZ+ software. The software is keyed to an individual AnalyzaVAC RGA unit. Each AnalyzaVAC RGA unit requires a separate software license. The software may be installed on any number of Windows computers to operate the instrument for which it is licensed. Software updates and unlock keys to the premium version are downloaded directly from this website.

Ideal Vacuum’s AutoZ+™ software is a Windows® 10 and 11, application that can control any Ideal Vacuum AnalyzaVAC™ residual gas analyzer from a computer or laptop. AutoZ+ software allows the user to control all RGA aquisition parameters and capture, view, and manipulate mass spectra. AutoZ+ is a stand-alone application that does not require an internet connection.

AutoZ+ Basic Version Features Include:
  • Analog, histogram, and intensity graph modes.
  • Full spectrum substance analysis of a limited library of atmospheric gases and common cleaning agents.
  • Access to calibration and aquisition settings.
  • Error, warning, and service alerts.
  • Limited reports capability to export aquired spectra.
  • Lifetime basic software license.
  • Free minor software updates when available.
  • Upgradable to the premium version at any time.

AutoZ+ Premium Version Added Features:
  • Log viewing, filtering, and averaging.
  • Logs export automatically or manually into industry standard CSV files.
  • Full reports and export capability.
  • Ability to save, load, and apply baseline files to live data or logs.
  • Annunciator alarms for process management.
  • Includes Ideal Vacuum's full substance library.
  • Capabiltiy to add to and edit the substance library.
  • Free future feature updates.
  • Simple online annual renewal.

AutoZ+ performs data collection and analytics on datasets returned from AnalyzaVAC RGA units. It can display the data as an analog spectrum, a histogram of peaks, or pressure trends of specific compounds or masses over time. The software automatically and rapidly performs full spectrum analyses of mass spectra to quantify the contribution of each identified gas to the displayed spectrum and the total system pressure.

AutoZ+ supports a wide range of processes including leak detection, residual gas and contaminant identification, outgassing analysis, and process monitoring. Ideal Vacuum's substance libraries and full spectrum analysis capabilities are invaluable features when monitoring critical system compositions.

Experienced users will appreciate Ideal Vacuum’s extensive full spectrum premium substance library and AutoZ+'s ability to apply baselines, providing the most accurate quantitative real-time gas compositions and partial pressures in the high and ultra-high vacuum regimes.

AutoZ+'s intuitive user interface makes it easy for new users to quickly calibrate the RGA, collect quality mass spectra, and analyze results. It also enables superusers to readily optimize specialized processes and experiments.

All AnalyzaVAC RGAs include a non-expiring basic version software license and a 60 day trial of all premium version features. The basic software may be upgraded to premium version at any time. AutoZ+ premium version software must be renewed annually or it will revert to the non-expiring basic version. Discounts for multiple, extended, or lifetime licenses are available. Some purchasers may be eligible for other discounts. Please speak to your sales representative.



Press ESC to Close




AnalyzaVAC REPLACEMENT PARTS
STYLE
100
100
Bare RGA
High Press. Kit
Range
1-100
1-100
Electron Multiplier
No
Yes
PART
New Probe
Refurbished Probe
P1013521
P1013527
Replac. Filament
Replac. Ionizer
Replac. Electron Multiplier
No
STYLE
200
200
Bare RGA
High Press. Kit
Range
1-200
1-200
Electron Multiplier
No
Yes
PART
New Probe
Refurbished Probe
P1013522
P1013528
Replac. Filament
Replac. Ionizer
Replac. Electron Multiplier
No
STYLE
300
300
Bare RGA
High Press. Kit
Range
1-300
1-300
Electron Multiplier
No
Yes
PART
New Probe
Refurbished Probe
P1013523
P1013529
Replac. Filament
Replac. Ionizer
Replac. Electron Multiplier
No
PDF Logo IVP AutoZ+ User Manual v1.2.0.1.pdf

PDF Logo IVP AnalyzaVac RGA User Manual v1.2.1.0.pdf



You may wish to consider the following products:

Ideal Vacuum Logo Water Mark
CONTACT US
Ideal Spectroscopy
5910 Midway Park Blvd NE,
Albuquerque, NM 87109-5805

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealspectroscopy.com



Press ESC to Close


deepbox image 2