Skip to main content
× Home Products Downloads About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
cart
 
Login Icon
login

Keyword       Ideal Spectroscopy Part Number       Manufacturer Part Number

× Molecular-Spectroscopy Optical-Table-Accessories Absorption-Spectroscopy-Gas-Cells Ultra-High Purity Gas Products Pulse-Valves-For-Jet-Cooling Vacuum-Pressure-Measurement Fittings-and-Flanges Vacuum-Valves Vacuum-Pumps Modular-Vacuum-Chambers

Condition:
  New
Part Number:
  P107962
Warranty:
  Agilent Warranty

Available Now: 
4  



$5,506.40


Regular Price: $6,883.00

On Sale Flyer
Print Version

Agilent Varian IDP-10 IDP10 Dry Scroll Vacuum Pump, 1-Phase, PN: X3810-64000


Agilent IDP-10 Hermetically-Sealed Dry Scroll Vacuum Pump, 120-240VAC, X3810-64000

The Agilent Varian IDP-10 dry scroll vacuum pump is designed for extremely quiet < 55 dBA and low vibration operation, delivering a peak pumping speed of 6.0 cfm (10.2 m3/h) at 60 Hz, and produces an ultimate pressure of 20 mTorr. A DSUB9 connector allows remote switching on/off of the pump as well as fine tuning of pump speed between 1350 and 1900 RPM. These new Agilent IDP-10 dry scroll pumps are hermetically-sealed and are appropriate for helium recirculation as well as vacuum oven, and backing pump applications. The hermetic design provides a clean gas path through the pump, which eliminates any risk of oil or grease contamination allowing the motor and bearings to run at atmospheric pressure, isolating them from exposure to vacuum process gases or water vapor. The Agilent IDP-10 supports a global single-phase motor for operating voltages ranges easily switched between 100-120V or 200-230 VAC at 50/60Hz.

This IDP-10 model, Agilent technologies part number X3810-64000, DOES NOT include the optional Integrated Inlet Isolation Valve which protects against backward migration of air through the scroll pump inlet if the IDP-10 loses power. This isolation valve prevents sudden venting of customer's chamber or instrument on system power loss.

High vacuum pumps, such as turbo molecular pumps, are increasingly used in conjunction with dry backing pump technology. Pumps based on scroll technology have become the dry pump technology of choice for backing turbo molecular high vacuum pumps. There are several factors that make these Agilent Varian IDP-10 scroll technology the superior dry pump choice, including clean, predictable performance, lower vibration and noise, and long service life.

Modern Agilent IDP-10 scroll technology is based on smooth orbital operation; the vacuum pump cycle of gas compression and discharge occurs with minimal pulsation and very low vibration. Depending on the application, vibration can have adverse effects, and may necessitate the use of additional components such as vibration isolators. The new Agilent IDP-10 is the dry pump of choice in a wide variety of applications where excessive vibration is unacceptable.

Current scroll pump technology and tip seal design are factors that work together to provide low base pressure, and a gradual increase in base pressure over the service life. This gradual increase in base pressure allows maintenance to be done before the vacuum levels become unacceptable and cuts unscheduled downtime. A typical scroll pump like the Agilent IDP-10 will achieve a base pressure of 20 mTorr.

These Agilent IDP-10 dry scroll pumps create vacuum using a simple dual scroll mechanism in which one of the nested scrolls orbits about the other, creating moving zones of captured gas. Gas enters the scroll set at the outside perimeter and is displaced and compressed toward the center of the hub where it is exhausted. The uncomplicated dual scroll design offers many benefits including lower noise and vibration levels, simple and infrequent maintenance requirements, plus the elimination of catastrophic failure modes.

These new Agilent Technologies IDP-10 includes improved solid tip seals for longer tip seal life and longer service interval. The solid tip seal material performs well for condensable vapor applications. The tip seal replacement for the IDP-10 is easier than ever before. In addition to a tip seal kit (X3807-67000), a few simple tools are all that is required to replace a worn tip seal: a flat head screw driver, 4 and 5 mm Allen wrenches, isopropyl alcohol, a few lint-free wipes. Please see pages 22 - 24 of the instruction manual for tip seal replacement procedure. An instruction manual and brochures in PDF format for the new Agilent IDP-10 hermetically-sealed dry scroll vacuum pumps can be downloaded in our available download section below.




Press ESC to Close


APPLICATIONS
    ACADEMIC & RESEARCH
  • Government Research Labs
  • University Labs
  • High Energy Physics/Beam Lines


  • INDUSTRIAL
  • Glovebox
  • Crystal Pulling
  • LED/Light Manufacturing
  • Freeze Drying
  • Gel Drying
  • Sample Preparation
  • Laser evacuation
  • Cryogenic dewars
  • Gas recovery and recirculation
  • Cryopump roughing
  • Vacuum chucks
    INSTRUMENTATION
  • Cryogenics
  • Electron Microscope
  • Helium Recirculation
  • Leak Detectors
  • Mass Spectrometry
  • Ion Implant
  • Leak Detection
  • Surface Science Instruments
  • Residual gas analyzers
  • Load locks for mass spectrometers
  • Electron microscopes
  • Surface area analyzers
  • EM Sample prep coaters


  • SEMICONDUCTOR FABRICATION
  • Gas panels
  • Gas delivery systems
  • Double wall containment vessels



PDF Logo Agilent Varian IDP Dry Scroll Vacuum Pump Family Brochure.pdf

PDF Logo Agilent Varian IDP-10 Oil-Free Dry Scroll Vacuum Pump Data Sheet.pdf

PDF Logo Agilent Varian IDP-10 Dry Scroll Vacuum Pump Instruction Manual.pdf

PDF Logo Agilent Varian Scroll Pumps vs. Diaphragm Pumps - Considerations.pdf

Ideal Spectroscopy offers 3D CAD models in Solidworks (SLDPRT), STP, & STEP formats. For those without CAD software a free trial 3D model viewer with measurement capabilities can be downloaded here:

E-drawing LogoeDrawings Viewer For Windows
E-drawing LogoeDrawings Viewer For MAC.




You may wish to consider the following products:

Ideal Vacuum Logo Water Mark
CONTACT US
Ideal Spectroscopy
5910 Midway Park Blvd NE,
Albuquerque, NM 87109-5805

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealspectroscopy.com



Press ESC to Close


deepbox image 2