Skip to main content
× Home Products Downloads About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
cart
 
Login Icon
login

Keyword       Ideal Spectroscopy Part Number       Manufacturer Part Number

× Molecular-Spectroscopy Optical-Table-Accessories Absorption-Spectroscopy-Gas-Cells Ultra-High Purity Gas Products Pulse-Valves-For-Jet-Cooling Vacuum-Pressure-Measurement Fittings-and-Flanges Vacuum-Valves Vacuum-Pumps Modular-Vacuum-Chambers

Condition:
  New
Part Number:
  P1012212
Warranty:
  18-Month Limited Warranty

Available Now: 
1  



$33,740.37


Regular Price: $43,256.89

On Sale Flyer
Print Version

Edwards ELD500 FLEX Helium Leak Detector Kit With 15.1 m3/h External nXDS15i Dry Scroll Pump & Mobile Cart. PN: D13530000


Edwards ELD500 FLEX Helium Leak Detector Kit With nXDS15i Dry Scroll Backing Pump and Mobile Cart Kit
Kit Includes HLD500 Flex (PN: D13530000), nXDS15i (PN: A73701983) and Mobile Cart (PN: D13550630).

These Edwards ELD 500 Flex helium leak detector high-performance mobile kit includes nXDS15i (15.1 m3/h) dry scroll backing pump.They are their most sensible design yet and offer amazing new features and control options for your facility, lab or classroom. For the ultimate control and customization for any application the ELD500 is your perfect solution for leak detection. At the push of a button the ELD500 can easily be set to work in either vacuum mode for precise measurement of leak rate or sniffer mode for identifying leak location. The minimum detectable leak rate available for this unit in vacuum mode is 5 x 10-12 mbar l/s and in sniffer mode 7 x 10-9 mbar l/s. The inlet flange on the Edwards ELD500 is DN KF25 and it comes standard with a TL7 internal calibrated leak and certificate of calibration. The Edwards ELD 500 helium leak detector operating instruction manual and product brochure can be downloaded in PDF format below. They operates on 1-phase 100-120 VAC 50/60 Hz and we offer optional accessories, such as, a trolley, transport case, remote control, spray gun, sniffer etc. This complete kit includes: HLD500 Flex (PN D13530000), nXDS15i (PN A73701983), Mobile Cart (PN D13550630), roughing pump mounting hardware, bellows hose, centering rings, and clamps.

The Edwards ELD 500 helium leak detector offers new features such as:
  • Contains a turbo primary pump and an internal 8.9 CFM (15.1 m3/h) nXDS15i dry scroll roughing pump
  • Quick Start up (< 2 minutes)
  • Helium Pumping Speed 3.1 l/s
  • Extremely fast response
  • DN KF25 Inlet Flange
  • Different reporting options - based on particular application needs
  • Auto Calibration
  • High Sensitivity
  • Flexible application areas
  • Maximum mobility with (optional) wireless or wired remote control ELD 500RC
  • Modular design makes this unit very service friendly
  • Most robust and reliable ion source (extended warranty time)

Optional Accessories for The Edwards ELD500 Helium Leak Detector:
  • Wired ELD 500 RC Remote Control PN D13550100
  • Mobile Trolley Cart D13550630
  • Helium Spray Gun PN 16555
  • Premium Helium Spray Probe Kit P1012177

Helium Leak Testing Basics
Helium mass spectrometry, or helium leak testing, is a highly precise means of leak detection. This technology was first developed for the Manhattan Project during World War II to locate extremely small leaks in the gas diffusion process.

At the heart of helium leak testing is a complex piece of equipment called a helium mass spectrometer. Quite simply, this machine is used to analyze air samples (which are introduced into the machine via vacuum pumps) and provides a quantitative measurement of the amount of helium present in the sample. In practice, a "leak," is identified by a rise in the level of helium being analyzed by the machine.

Helium leak testing can identify extremely small leaks. For example, our equipment can detect a leak so small that it would emit just two cubic centimeters of helium (or the amount equal to two sugar cubes) in 320 years. While very few applications require this level of precision, this example serves to highlight the accuracy possible with this process.

While helium leak detection may appear to be a simple procedure, the process involves a combination of both art and science. The user must ensure the equipment is functioning properly and the process is highly dependant upon the user’s experience. Consider this analogy: while anyone with enough money can buy an airplane, learning how to fly one takes a lot of practice. The same is true with helium leak detection-make sure your "pilot" knows how to fly.

Why Is Helium Superior?
While many gases are used in leak detection, helium’s qualities provide for superior testing. Having an AMU (Atomic Mass Unit) of only 4, helium is the lightest inert gas. Only hydrogen, with an AMU of 2, is lighter than helium. However, due the hydrogen’s explosive potential it is rarely used.

Additional reasons why helium is a superior tracer gas:

  • Only modestly present in the atmosphere (roughly 5 parts per million)
  • Flows through cracks 2.7x faster than air
  • Nontoxic
  • Nondestructive
  • Nonexplosive
  • Inexpensive
  • User Friendly

Due to these attributes, and its high sensitivity, helium leak testing has gained broad acceptance in a wide range of leak testing applications. Helium Leak Testing’s two primary testing modes while there are a variety of testing procedures, in general there are:

Two primary methods of helium leak testing:

  • Spray Probe
  • Sniffer Probe

The choice between these two modes is based on both the size of the system being tested, as well as, the level of sensitivity required.

Spray Probe: Provides Maximum Sensitivity
For this technique, the leak detector is hooked directly to the system under test and the inside of the system is evacuated. Once an acceptable vacuum is achieved, helium is sprayed discreetly on the outside of the system, with particular attention being paid to any suspect locations. Any leaks in the system, including defective welds (caused by cracks, pin holes, incomplete welds, porosity, etc.), flawed or missing gaskets, leaks due to loose clamps, or any other defect will allow helium to pass and be readily detected by the machine. The source of any leaks can then be accurately pinpointed and repaired.

The spray probe process is used to achieve the highest level of sensitivity. The equipment being used dictates the maximum sensitivity achievable; in Jurva Leak Testing’s case it is 2x10-10 std cc/sec. This technique does require that the system being tested is relatively leak tight prior to testing, as an ample vacuum is required for testing. However, by using special throttling devices a gross test can typically be performed. The gross test should eliminate any major leaks, permitting the use of increased sensitivity.

The following are examples of systems that we test using the spray probe technique:

  • A-bar furnaces
  • E-beam systems
  • Laser systems
  • Metal deposition equipment
  • Distillation systems
  • Vacuum systems

Sniffer Probe
For this technique, helium is purged throughout the inside of system being tested. Due to the innate properties of helium it readily migrates throughout the system and in its attempt to escape penetrates any imperfections, including: defective welds (caused by cracks, pin holes, incomplete welds, porosity, etc.), flawed or missing gaskets, leaks due to loose clamps, or any other defect. The system’s exterior is then scanned by using a probe attached to the leak tester. Any leaks will result in an increased level of helium nearest the source and be readily detected. Leak sources can then be pinpointed, providing the opportunity for immediate repair and retest.

Unlike the spray probe technique, this process is very flexible and can be adapted to meet the needs of any virtually any system in which helium can be injected. There is no practical size limitation. The sniffer probe technique is not as sensitive as the spray probe process, however, due to the amount of helium present in the air (approximately 5 ppm). The maximum sensitivity achievable under this procedure is approximately 1x10-6 std cc/sec. Nevertheless, this process is vastly superior to other traditional leak testing methods, such as: bubble testing, acoustic emission, liquid penetrant or vacuum box testing.

The following list is an example of systems that Jurva Leak Testing has tested using the sniffer probe process:

  • Storage tanks (both above ground and below)
  • Floating roofs
  • Underground pipelines
  • Underground cables
  • Aseptic systems (flash coolers, heat exchangers, fillers, etc.)
  • Any vessel/line or system that can be pressurized



Press ESC to Close




Availability Of Kit Components

Kit: P1012212 - Edwards ELD500 FLEX Helium Leak Detector Kit With 15.1 m3/h External nXDS15i Dry Scroll Pump & Mobile Cart. PN: D13530000
Component
Desc.
Req'd
Avail
Hinge Clamp KF-25 Vacuum Fittings, ISO-KF Flange Size NW-25, Aluminum
2
15498
Centering Ring KF-25 Vacuum Fittings, ISO-KF Flange Size NW-25, Stainless Steel & Viton O-ring
2
16983
Bellows Hose Metal KF-25, 40 Inch, Thin Wall Tubing, ISO-KF Flange Size NW-25, Stainless Steel
1
138
Edwards nXDS15i Oil-Free Dry Scroll Vacuum Pump, 100-240 VAC, 8.9 CFM. PN: A73701983
1
3
Edwards ELD500 FLEX Helium Leak Detector, No Internal Backing Pump, External Backing Pump Required, Edwards Vacuum PN D13530000
1
1
EDWARDS Mobile Trolley Cart for the ELD500 Helium Leak Detector. PN: D13550630
1
2
PDF Logo Edwards ELD500 Helium Leak Detector Instruction Manual.pdf

PDF Logo Edwards ELD500 Leak Detection Data sheet.pdf

PDF Logo Edwards ELD500 Leak Detection Brochure.pdf

PDF Logo Edwards Mobile Trolley Cart for the ELD500 Helium Leak Detector_Data-Sheet.pdf

Ideal Spectroscopy offers 3D CAD models in Solidworks (SLDPRT), STP, & STEP formats. For those without CAD software a free trial 3D model viewer with measurement capabilities can be downloaded here:

E-drawing LogoeDrawings Viewer For Windows
E-drawing LogoeDrawings Viewer For MAC.




You may wish to consider the following products:

Ideal Vacuum Logo Water Mark
CONTACT US
Ideal Spectroscopy
5910 Midway Park Blvd NE,
Albuquerque, NM 87109-5805

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealspectroscopy.com



Press ESC to Close


deepbox image 2