This is a long CGA-350 to 1/4" MNPT nickel-plated brass fitting with left-handed threads. Nipple length is 3.0 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and a maximum pressure of 3000 psig. This CGA-350 fitting, PN: SEQ3504BpL, is rated for use with the gases listed below.
CGA-350 for use with:
- Hydrogen
- Methane
- Carbon Monoxide
- Arsine
- Deuterium
- Deuterium Selenide
- Diborane
- 1,1 Difluoroethylene
- Ethane
- Ethylene
- Germane
- Hydrogen Selenide
- Methyl Fluoride
- Methylene Fluoride
- Natural Gas
- Pentaborane
- Phosphine
- Silane
- Stibine
- Tetrafluoroethylene
- Vinyl Fluoride
CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads).
Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.